MODULE 2: UPPER Console-2

2020-02-08  本文已影响0人  hi武林高手

Enabling Objective#2
A. State the specification of the air supply and the system pneumasics used on the IConn machine
B. Select proper control on the pneumatics panel and set according to the K&S specifaction

Manifold Front view
pneumatic Control & Indicators
Manifold Real view
Pneumatic Control & Indicators
pneumatic Schematic Diagram
pneumatic Control & Indicators

The following pressure settings serve as a guideline:

--Air guide pressure setting are similar to Ultra

-- Tensioner pressure settings have been rescaled to provide more resolution Recommended pressure Settings
NOTE:

These setting may be changed as needed when operating the machine

Looping Conversion Guideline

When loading an Ultra bond program on Iconn:
-Existing loop shapes are supposd.
-No bond parameter changes are required.
-If portablilty is desired,the wirefeed settings should be set according to the table below



Some challenging applications may require fine tuning of looing parameters such as loop factors, shape factor,or throttles to compensate foe the increase in ICONN speed.