MODULE 2: UPPER CONSOLE-3

2020-02-09  本文已影响0人  hi武林高手

Enabling Objective #3
Demonstrate the preventive maintenance for the pneumatics used on the Iconn machine

Air Guide Cleaning

air guide cleaning

Remove & Clean Air Tensioner


Detail

Air Tensioner to Transducer Alignment

Tools needed--Tensioned Alignment Fixgure P/N 08888-0036-000-00

Force sensor Calibration Tool


P/N 08858-0901-001-00

--Replace capillary with Force Sensor Calibration Tool on the transducer(Optional)

--Activate Z chess and press the"Down arrow key" on the MMI till Z axis value reaches o mil.
--Place the alignment jig into the force sensor calibration tool and ensure jig is flushed to the transducer surface




--Loose the lock screw on the Tensioner Alignment Jig and adjust rod till it touches the tensioner lower ceramic tube
--Loosen the Y and X axis locking screw for the tensioner on the optical housing assembly

-Adjust the Tensioner and ensure assembly is aligned with the Transducer
-Tighten Tensioner assembly X and Y adjustment screws